Feasibility study of a LYSO SiPM based prototype for hybrid Compton and PET imaging

请选择邀稿期刊:
Краткое изложение: We present a prototype for hybrid Compton and positron emission tomography (PET) imaging aimed at enhancing data utilization and enabling concurrent imaging of multiple radiopharmaceuticals. The prototype comprises two detectors that utilize LYSO-SiPM and were available in our laboratory. One detector consists of a 50 × 50 array of LYSO crystals, each measuring 0.9 mm × 0.9 mm × 10 mm with 1 mm pitches, whereas the other detector comprises a 25 × 25 array of LYSO crystals, each measuring 1.9 mm × 1.9 mm × 10 mm with 2 mm pitches. These detectors are mounted on a rotational stage, which enables them to function as either a Compton camera or a PET detector pair. The 64-channel signals from the SiPMs of each detector are processed through a capacitive multiplexing circuit to yield four position-weighted outputs. Distinct energy windows were used to discriminate Compton events from PET events. Energy resolution and energy-channel relationships were calibrated via multiple sources. The measured average energy resolutions (full widths at half maximum, FWHMs) for the detectors at 511 keV were 17.5% and 15.2%, respectively. The initial experimental results indicate an angular resolution (FWHM) of 8.6 ◦ for the system in Compton imaging mode. A V-shaped tube injected with 18F solution was clearly reconstructed, which further verified the imaging capabilities of the system in Compton imaging mode. The results of simulation and experimental imaging studies show that the system can detect tumors as small as 1 mm in diameter when working in PET imaging mode. Mouse bone PET imaging was successfully conducted, with the results matching well with the corresponding CT images. This technology holds great potential for advancing the development of physiological function modalities.
  • из 王海浩
  • Категоризация: 核科学技术 >> 核仪器、仪表
  • инструкции: 目前已被NST录用,等待正式见刊阶段。作者目前的一些项目评定需要该文章作为学术成果之一,因此提前上传预印本作为成果证明。
  • Состояние представления: 已被期刊录用
  • Цитировать: ChinaXiv:202507.00140 (или эта версия ChinaXiv:202507.00140V1)
    DOI:10.12074/202507.00140
    CSTR:32003.36.ChinaXiv.202507.00140
  • Рекомендуемое цитирование: 王海浩,侯禹存,花健朗,袁子泉,李晨曦,廖润泽,江建勇.Feasibility study of a LYSO SiPM based prototype for hybrid Compton and PET imaging.null.[DOI:10.12074/202507.00140] (Нажмите здесь, чтобы скопировать)

История версий

[V1] 2025-07-05 21:46:21 ChinaXiv:202507.00140V1 Скачать полный текст
Нажмите, чтобы загрузить полную версию статьи
Осмотр
Состояние экспертной оценки
Будет рассмотрено
Лицензионное заявление
стандарт
  •  Количество сортировки268
  •  Количество загрузок 36
комментарии
делиться с другими
Заявка на экспертизу